Ç° ¸í
Æ÷À¯·ù ¼¼Æ÷ ¹è¾ç¿ë
Ç׿ ÁøÅÁ ¹è¾ç±â
¸ðµ¨¸í
CO2-BR Series
Á¦Á¶±¹
JAPAN
Á¦Á¶»ç
TAITEC
< Constant temperature shaking incubator for mammal cell culture >

    Á¦Ç° »ç¾ç
 
1. »ç¿ë ¿Âµµ ¹üÀ§ 23FP£º+15¡É~+50¡É 
                  40LF/43FL/180LF£º+4¡É~+50¡É 
2. ÁøÅÁ ¼Óµµ      23FP/40LF/43FL£º20~200r/min 
                  180LF£º25~200r/min 
   ¡Ø±× ¿ÜÀÇ »ç¾ç ±âº»ÀÇ ¹ÙÀÌ¿À ½¦ÀÌÄ¿¿Í µ¿µî. 
     ¿Âµµ³ª ÁøÅÁ ¼ÓµµÀÇ »óÇÑÀº ¿ëµµÀÇ °üÁ¡À¸·ÎºÎÅÍ
	 ±âº»º¸´Ù ³·Àº °ªÀ¸·Î º¸Áõ. 
3. »ï°¢ Çöó½ºÅ©°¡¼ö(Ç¥ÁؽÃ)
    23FP£º125 ml ¶Ç´Â 250ml¡¿6 
    40LF£º500ml¡¿6 
    43FL£º1L¡¿6 
    180LF£º1L¡¿12 
    ¿ëµµ ¹× Ư¡

 Æ÷À¯·ù ¼¼Æ÷ ¿Ü¿¡µµ Çø±â¼º ¹Ì»ý¹°µîÀÇ
 ¹è¾ç¿¡ »ç¿ëÇÒ ¼ö ÀÖ´Â °í°´´ëÀÀ ¹ÙÀÌ¿À ½¦ÀÌÄ¿. 
 ¿ëµµ
 ºÎÀ¯¼ºÀÇ Æ÷À¯·ù ¼¼Æ÷(CHOµî)ÀÇ ¹è¾ç 
 Ç×ü »ý»êÀÇ È¿À²È­ 
 293 ¼¼Æ÷ÀÇ Æ®¶õ½ºÆäÅ©¼ÇÀ̳ª ¹è¾ç 
 ¹ÌÈ£±âºÐ¡¤Çø±â¼º¼¼±Õ(ºñÇÇ´õ½º±ÕÀ̳ª ÇǷθ®±Õµî)ÀÇ ¹è¾ç

 
    Á¦Ç° »ó¼¼ Á¤º¸
A. Feature: 
1. The main body of the culture machine can be selected according to the scale of culture. 
   The one that the gas divergence tube was installed in constant temperature shaking culture
   machine "Biotechnology shaker" of Taitec is "Custom biotechnology shaker CO2-BR series."
   We have four models (convenient, medium CO2-BR-43FL and large-scale CO2-BR-180LF in standard,
   medium CO2-BR-40LF of desk-top small CO2-BR-23FP and transparent food, shading by the standard.


2. There is a type to be able to control oxygen and nitrogen by adding the gas controller
   (optional) to the type and carbon dioxide that controls only the selection carbon dioxide
   by two models. Moreover, we will prepare the Nitrogen generation device in the supply of
   Nitrogen gas.  

3. There are results also in the culture of the anaerobic microorganism.
   In the combination of the multi gas controller and Nitrogen gas supply device,
   it is possible to use it also for the culture of bifidus bacteria and Helicobacter Pylori. 

4. Customize it further by the custom-designed correspondence. 
   It is also possible to remodel from a biotechnology shaker on hand and to allot the main
   body of the culture machine. Moreover, number of Erlenmeyer flask(= number of gas divergences)
   is changed, and the  container can be made a chamber type and the dish and the culture plate
   be used. 


B. Specifications: 
1. Temperature Range  23FP£º+15¡É~+50¡É
                      40LF/43FL/180LF£º+4¡É~+50¡É 
2. Shaking speed      23FP/40LF/43FL£º20~200r/min
                      180LF£º25~200r/min 
   ¡ØIt is equal to the biotechnology shaker of other specification bases.
     The upper bound at the temperature and the shaking speed is guaranteed from the
     viewpoint of the usage by a value that is lower than the base machine.
3. Number variation of Erlenmeyer flask(At the standard)
                                  23FP:125ml or 250ml¡¿6 
                                  40LF:500ml¡¿6 
                                  43FL:1L¡¿6 
                                  180LF:1L¡¿12 
4. Variation 1 of Number changes 23FP:  none 
                                 40LF:250ml¡¿6 or 250ml¡¿12 or 3L¡¿1 
   Variation 2 of Number change 43FL:250ml¡¿6 or 250ml¡¿12 or 500ml¡¿6 or 3L¡¿1 
                                180LF:3L¡¿4.
   - Cost of No. change:  Separate with the price of the main body.  
5. Separate necessary goods 1  10kg bomb such as 100% carbon dioxide
                               (no manufacturing in Taitec)
                               Regulator
   necessary goods 2 flask cap(half article of consumption, 6pieces)
   necessary goods 3 Erlenmeyer flask
   (Corning, No.430183/430422/431146/431252 recommendation)
   necessary goods 4 Air filter(half article of consumption, 50ea)
   necessary goods 5 Gas supply Hose(half article of consumption, 6pair)